HMP Metallized Polypropylene Film
For Interference
Suppression and Across-The-Line, Class X1
|
|
 |
HMP are non-inductively wound with a metallized
polypropylene film dielectric/electrode, encapsulated in flame retardant (UL94, V-O)
plastic case and epoxy resin end seal
1 HMP-A ... Fastion terminals.
2 HMP-S ... Tinned copper clad steel wire radial leads.
3 HMP-W ... Soldering terminals.
4 HMP-P ... UL 1015 or UL 1007 stranded PVC insulation wire.
|
|
|
- Base Specification:
a)IEC 33(C0) 77 ... Used for AC motor application
b)JIS C 4908 ... Used for electrical apparatus
- Climate Category: In accordance with
DIN40040 HSF
a)H=Minimum Limit Temperature ... -25
b)S=Maximum Limit Temperature ... +70
c)F=Humidity category ... Average relative humidity 75%, 95% for 30 days, per year, continuously; 85% for the
remaining days, occasionally.
- Rated Voltage: ............. 250, 350, 400,
450 V.AC, 50~60Hz
- Capacitance Range: .............0.1~15.0
F
- Capacitance Tolerance: J(
5%), U( +10, -5%), K( 10%)
- Withstand Voltage:
a)Between Terminals ... 1.5 x rated voltage for 10s.
b)Between Terminals and Case ... 2 x rated voltage + 1000 V (1500 V Min.) for 60s.
This test occasional self-healing breakdown are allowed.
- Dissipation Factor:
0.1% at 200 V . AC, 60 Hz and 20
- Insulation Resistance:
a)Between Terminals ...
10 x 103 M for C 1.0 F; 1 x 103 M / F
for C> 1.0 F;
b)Between Terminals and Case.... 10 x 103 M Measured at 100
V.DC, 60s and 20
|
|
| TAIWAN LEADERS CENTER 8F-A2 NO.29 HAI-PIEN ROAD, KAOHSIUNG, TAIWAN, R.O.C. TEL : 886-7-3353075 FAX : 886-7-3389030 |